In traditional atmospheric burners, the combustion gas is ejected from the nozzle and then entrains air, resulting in uneven mixing and a significant temperature gradient in the flame. Localized high-temperature zones produce large amounts of thermal nitrogen oxides.NOxFully premixed technology, through a variable frequency fan and a Venturi mixer, uniformly mixes natural gas and air at a stoichiometric ratio before they enter the burner. During combustion, the flame is short and uniform, with almost no localized high-temperature zones.NOxThe generation rate can be significantly reduced.
NOx The generation of [something] is highly correlated with the peak flame temperature. Fully premixed [something]+The metal fiber burner head stabilizes the flame temperature.800~900°C The range avoids1200°C The above refers to the high-temperature core area. Currently, the mainstream low-NOx condensing water heaters on the market... (The sentence is incomplete and requires further context to be translated accurately.)NOx Concentration can generally be controlled at30 mg/m³ Within this range, it meets the low-nitrogen transformation requirements of key areas.
The main component of natural gas is methane (CH₄When the flue gas is completely burned, it produces a large amount of water vapor. When this water vapor is directly emitted at high temperature, its latent heat of vaporization is wasted. A condensing heat exchanger reduces the flue gas temperature from...150~200°C Down to60°C The following process causes water vapor to condense and release heat. Each condensation...1 kg Water vapor, approximately [amount missing] can be recovered.2400 kJ Heat. Therefore, the overall thermal efficiency of the machine can be improved from that of the standard type.88%~90% Upgraded to102%~108%(Calculated based on lower heating value).
Technical Module | Key role | User benefits |
Fully premixed | Evenly mixed, stable combustion | Low noise and high combustion efficiency |
Metal fiber burner | Suppressing local high temperature | NOx Low cost and meets environmental protection requirements |
Condensing heat exchanger | Recovery of latent heat of water vapor | Energy saving 10%~15% |
Free energy RSTD series(45~495 kWCommercial storage gas water heaters, specifically those employing fully premixed low-NOx condensing technology. This series has a rated heat load coverage...45 kW to99 kWMultiple units connected in parallel can meet the needs of medium and large-scale centralized hot water projects. Flue gas emissions meet the low-nitrogen retrofit standards of key cities in China, and the thermal efficiency of the hot water system is better than the national first-level energy efficiency index.