Free energy - make heating simpler, safer, more energy-saving and smarter! Freedom = autonomy/ego
Search

White Paper on Free Energy Flat Square Stacked Fully Premixed Modular Furnace Technology

2026-09-10 15:06

White Paper on Free Energy Flat Square Stacked Fully Premixed Modular Furnace Technology

Version: V1.0

Release date: July 2026

Prepared by: Foshan Free Energy Electrical Appliance Co., Ltd

catalogue

· Chapter 1 Overview and Technical Background

· Chapter 2 Precision Stacking Heat Transfer Technology of Flat Square Tube

· Chapter 3: Fully Premixed Surface Combustion System - Flat Plate Generous Burner

· Chapter 4: Intelligent Control System for Stepped Gas Proportional Valve

· Chapter 5 Modular System Architecture and Parallel Operation

· Chapter 6 Product Series and Technical Parameters

· Chapter 7 Horizontal Comparative Analysis of Four Mainstream Boiler Structures

· Chapter 8 Application Scenarios and Selection Guidelines

· Conclusion

Chapter 1 Overview and Technical Background

1.1 Industry Background

The commercial hot water and industrial heating fields have long faced three core contradictions: the contradiction between thermal efficiency and volume, the contradiction between low nitrogen emissions and combustion stability, and the contradiction between equipment reliability and operation and maintenance costs. The traditional boiler technology route often neglects one aspect when solving the above contradictions - pursuing high efficiency requires increasing the heat exchange area, but increasing the heat exchange area means volume expansion; The pursuit of low nitrogen emissions requires fully premixed combustion, but fully premixed systems have extremely high requirements for air-fuel ratio control accuracy, which traditional passive adjustment methods are difficult to meet; The pursuit of reliability requires redundant design, but redundancy leads to increased costs.

At the same time, the regulation of atmospheric pollutant emissions from boilers by the government continues to tighten. The "Boiler Air Pollutant Emission Standards" (GB 13271-2014) stipulate that the NOx emission limit in key areas is 30mg/m ³, and the "ultra-low emission" policies in various regions further require NOx to be ≤ 30mg/m ³ or even lower. The Special Equipment Safety Law implements strict registration, annual inspection, and certification management system for pressure boilers, resulting in high usage costs and management thresholds.

In this context, Free Energy is based on the product concept of "making heating simpler, safer, more energy-efficient, intelligent, and durable". After years of research and development, it has innovatively launched a flat stack fully premixed modular furnace product system, covering two series of modular water heaters and modular steam generators. With three self-developed core technologies - flat stack heat transfer, adaptive fully premixed combustion control, and flat plate ample burner - it systematically solves the above industry contradictions.


1.2 Technical positioning

The free energy flat square stacked fully premixed modular furnace belongs to the fourth generation fully premixed low nitrogen condensing boiler technology. From the perspective of the evolution of boiler technology:

intergenerational

Technical route

thermal efficiency

NOx排放

NOx emissions

typical characteristics

the first generation

Atmospheric combustion

90-92%

80-150mg/m³

1:2-3

Natural gas inhalation, low efficiency, high emissions

the second generation

Partial premixed combustion

92-95%

50-80mg/m³

1:3-4

Partial pre mixing, limited improvement

the third generation

Fully premixed surface combustion

100-103%

30-50mg/m³

1:4-5

Improved combustion efficiency, but insufficient control accuracy

the fourth generation

Flat stacked fully premixed condensation

≥107%

<30mg/m³

1:10

Stacking of flat square tubes for heat exchange+active intelligent control+condensation recovery

The core breakthrough of the fourth generation technology lies in replacing traditional circular tube heat exchangers with precision stacked flat square tube heat exchangers, achieving a leapfrog increase in the ratio of heat transfer area to volume at the geometric structure level; Replacing traditional passive Venturi proportional valves with electric proportional valves driven by stepper motors, achieving active and precise closed-loop control of air-fuel ratio from the control level; Replacing traditional metal fiber mesh burners with flat and spacious burners to achieve maintenance free, long-term stable operation at the combustion level.

1.3 Overview and Corporate Culture of Free Energy Enterprises

Foshan Free Energy Electrical Appliance Co., Ltd. was established in 2016, headquartered in Shunde, Foshan, Guangdong. In 2021, it purchased a factory in Wanyang Creative City, Heshan, Jiangmen and introduced a robot production system. The enterprise focuses on the in-depth development and innovation of gas energy-saving thermal energy products, adheres to the independent research and development technology route, insists on using domestically produced universal spare parts, and is committed to providing users with Chinese style thermal freedom.

The deep connotation of the brand name "Free Energy" and corporate culture:

The three words' Free Energy 'are not only a brand name, but also a condensed version of the corporate spirit.

'Self' - autonomy. Independent research and development, independent production, and independent controllability. Freedom can firmly believe that core technologies cannot be bought or sought after, and only through independent mastery can we avoid being "choked". From the structural design of the flat square tube heat exchanger, the development of the flat and wide width burner, to the control algorithm of the step by step gas proportional valve, each core technology is independently completed by the enterprise. In the selection of spare parts, the enterprise insists on using domestically produced universal spare parts to ensure the safety and controllability of the supply chain, convenient after-sales replacement, and truly achieve full chain autonomy from research and development to after-sales.

'From' - I hold onto it. The relentless pursuit of ultimate technology and the persistent adherence to the bottom line of quality. 'Self obsession' is not stubbornness, but the engineer's obsession with 'doing the best'. Every optimization of the precision stacking process for flat square tubes, every size correction of the burner channel, and every closed-loop iteration of the control algorithm all stem from the engineer's obsession with "not compromising and not compromising". It is precisely this' self obsession 'that enables free energy to achieve the smallest volume, largest heat exchange area, and highest thermal efficiency at the same power, pushing the fully premixed technology to new heights.

'Energy' - energy. Liberate energy efficiency through technology and reduce energy consumption through innovation. The mission of Free Energy is to generate more heat per cubic meter of gas, ensure that every device runs longer and more stably, and reduce heating costs for every user. Free energy "refers to" infinite energy "- through technological progress, energy utilization approaches physical limits, allowing limited resources to unleash infinite possibilities.

The enterprise holds an industrial production license, has passed the certification of quality management system, occupational health management system, and environmental management system, and has a complete third-party testing report. The flat square stacked fully premixed module furnace is the culmination of the free energy independent technology system, representing the latest breakthrough of enterprises in the field of fully premixed low nitrogen condensation.


Chapter 2 Precision Stacking Heat Transfer Technology of Flat Square Tube

2.1 Technical Principles

2.1.1 Physical essence of boiler heat exchange

The physical essence of a boiler is a gas water heat exchanger. Gas combustion produces high-temperature flue gas, and the thermal energy of the flue gas is transferred to the water through the wall of the heat exchanger. According to the fundamental laws of heat transfer:

Q = K × A × ΔT

Where Q is the heat transfer amount, K is the heat transfer coefficient, A is the heat transfer area, and Δ T is the logarithmic mean temperature difference.

Under the premise of determining the type of gas and combustion method, the variation space of K value and Δ T value is limited. Therefore, increasing the heat exchange area A is the most direct and effective engineering path to improve thermal efficiency. However, increasing the heat exchange area of traditional boilers inevitably leads to equipment volume expansion, increased metal consumption, and rising manufacturing costs, forming a "efficiency volume cost" triangle dilemma.

2.1.2 Geometric limitations of circular tube heat exchangers

Traditional boilers commonly use circular cross-section pipe fittings as heat exchange elements. The geometric characteristics of circular pipe fittings determine that there is a natural upper limit to their spatial filling rate:

· When arranging circular pipes, there must be arc-shaped gaps ("dead zones") between the pipes, which cannot be effectively utilized

· Under tight arrangement conditions, the theoretical maximum space filling rate of a circular tube is about 78.5% (π/4), while in practical engineering, it is usually only 60-70%

· Increasing the pipe diameter can increase the heat transfer area of a single tube, but the spacing between tubes increases synchronously, resulting in a decrease in filling rate instead of an increase

· Reducing the pipe diameter can improve the filling rate, but the water flow resistance inside the pipe increases sharply, and the manufacturing difficulty and cost significantly increase

This means that there is a theoretical limit to the ratio of heat transfer area to volume (hereinafter referred to as the "aspect ratio") within the circular tube framework, and the aspect ratio of traditional circular tube boilers remains stagnant at around 1.0 for a long time.

2.1.3 Geometric breakthrough of flat square tube

Freedom can creatively replace circular pipe fittings with rectangular flat square tubes. Rectangular flat square tubes have the geometric advantage of bidirectional extremes:

· Arrangement direction: The faces of the flat square tube are tightly adhered to each other, and the gap between the tubes approaches zero, with a space filling rate of over 95%

· Heat transfer direction: The wide surface of the flat square tube faces the flue gas channel, and under the same windward area, the heat transfer wall area through which the flue gas flows is much larger than that of the circular tube

· Thickness direction: Flat square tubes can be made extremely thin in the thickness direction, allowing for stacking more layers of pipe fittings in limited space

Multiple flat square tubes are stacked and welded layer by layer through precision brazing technology to form an integrated heat exchanger core. This structure achieves bidirectional synchronous optimization of minimizing volume and maximizing heat transfer area, with a face to surface ratio of 1.6-1.8, which is 60-80% higher than traditional circular tubes.

2.1.4 Integrated molding condensation recovery

The flat stacked heat exchanger adopts an integrated design of heat exchanger and condenser. High temperature flue gas enters from the top and passes through the flat tube bundle layer by layer from top to bottom. During the heat exchange process, the flue gas temperature continues to decrease. When the smoke temperature drops below the dew point of the flue gas (natural gas flue gas dew point is about 55-60 ° C), the water vapor in the flue gas condenses into liquid water, releasing the latent heat of vaporization. This latent heat is absorbed by the wall of the heat exchanger and transferred to the water, resulting in a thermal efficiency exceeding 100% (calculated based on low heat generation), which has been measured to reach 107% -108%.

The final exhaust temperature is as low as 45 ° C, which means that the sensible and latent heat of the flue gas are fully recovered. Low temperature flue gas can be discharged through PVC pipes, further reducing the cost of smoke exhaust engineering.


2.2 Material selection

The flat stacked heat exchanger is made of 316L stainless steel. 316L is a low-carbon variant with reduced carbon content (C ≤ 0.03%) based on 316 stainless steel, and has the following key characteristics:

characteristics

indicator

Engineering significance

high temperature resistance

Can withstand long-term erosion from 1000 ° C high temperature flue gas

Ensure that the heat exchanger does not deform or burn under extreme working conditions

Corrosion resistance

Molybdenum element (Mo 2-3%) enhances pitting corrosion resistance

Resist acidic corrosion (pH 3-4) and chloride ion erosion caused by condensed water

Waterproof to alkali

Dense and stable surface passivation film

Adapt to different water quality conditions in China, with strong anti scaling ability

Pressure resistance

Yield strength ≥ 210MPa

Rated pressure of 1.0Mpa, meeting the requirements of pressure operation

solderability

Low carbon content reduces carbide precipitation in welding heat affected zone

Reliable guarantee of precision brazing stacking process

Compared with the commonly used carbon steel (easily corroded by condensed water, short service life), cast aluminum (not acid resistant, prone to leakage and irreparable), and copper (not high temperature resistant, high cost) in traditional boilers, 316L stainless steel has comprehensive advantages in temperature resistance, corrosion resistance, pressure resistance, and service life, making it the optimal material choice for heat exchangers in fully premixed condensing boilers.

2.3 Core Technical Indicators

parameter

Traditional round tube heat exchanger

Flat square tube precision stacked heat exchanger

Heat exchange area/volume ratio

1.0

1.6-1.8

Same power volume

100% (benchmark)

20-35%(Only traditional1/3-1/5)

Same volume heat exchange area

100% (benchmark)

300-400%(Traditional 3-4 times)

Heat exchanger material

Carbon steel/cast aluminum/copper

316L stainless steel

Temperature endurance limit

400-600°C

1000°C

Pressure-bearing capacity

0.1-0.7Mpa

1.0Mpa

Water volume

>50LMost of them are pressure vessels

<30L(Non pressure vessel)

Taking a 180KW single module as an example:

·Heat exchange area of water heater: 26.64 ㎡

·Steam generator heat exchange area: 36.55 ㎡

·Water capacity:<30L (water heater)/24.28L (single module steam generator)


2.4 Regulatory Value of Non Pressure Vessels

According to the Special Equipment Safety Law and the Safety Technical Supervision Regulations for Fixed Pressure Vessels (TSG 21-2016), pressure equipment with a water volume of ≥ 30L is classified as a pressure vessel and must be included in special equipment management. It is required to obtain a registration certificate for use, conduct regular annual inspections, and be equipped with a certified stoker.

The free energy flat square stacked heat exchanger is designed with precision stacking of flat square tubes, ensuring a large heat transfer area while controlling the water volume of a single module within 30L (the steam generator module only has 24.28L), and is not a pressure vessel. This breakthrough in the project brings significant regulatory value:

·Exemption from inspection: No need to register the use with the special equipment supervision and management department

·Certificate free: No need to apply for a registration certificate for the use of special equipment

·Exemption from annual inspection: No need for regular annual inspections

·Boiler free worker: The equipment operates fully automatically, without the need for a certified boiler operator

·Pressure bearing operation: Although not classified as a pressure vessel, it is designed to withstand a pressure of 1.0Mpa, which can meet the requirements of pressure heating systems

This significantly reduces the user's usage threshold and overall management costs, making it particularly suitable for commercial and industrial scenarios that require high compliance and ease of management.


Chapter 3: Fully Premixed Surface Combustion System - Flat Plate Generous Burner

3.1 Principle of fully premixed combustion

3.1.1 Comparison of combustion methods

The combustion method of a gas boiler determines the combustion efficiency and pollutant emission level. The main combustion methods are compared as follows:

Combustion method

Mixed method

Flame form

thermal efficiency

NOx emissions

Adjustment ratio

Diffusion combustion

Gas and air mix in the combustion zone

Diffuse flame (long flame)

88-90%

100-200mg/m³

1:2

Atmospheric combustion

Partial Premixing (Primary Air Coefficient 0.4-0.6)

Partial premixed flame

90-92%

80-150mg/m³

1:2-3

Partial premixed combustion

High degree pre mixing (primary air coefficient 0.7-0.9)

Short flame

92-95%

50-80mg/m³

1:3-4

Fully premixed surface combustion

Gas and air 100% premixed (excess air coefficient 1.15-1.25)

Flameless surface combustion

≥107%

<30mg/m³

1:10

The core principle of fully premixed surface combustion is to thoroughly mix gas and air in the optimal ratio before combustion. The mixed gas is ignited when passing through the surface of the porous medium, forming a uniform flameless combustion on the surface of the medium. Due to complete mixing, thorough combustion, low and uniform flame temperature, the production of thermal NOx is significantly reduced.

3.1.2 Key challenges of fully premixed combustion

Although fully premixed combustion has high efficiency and low emissions, it faces three major challenges in engineering applications:

1. Accuracy of air-fuel ratio control: Full premixed requires precise matching of the ratio of gas to air, and a deviation of more than 5% can lead to unstable combustion or NOx exceeding the standard

2. Dust accumulation and blockage in the burner: Fully premixed burners usually use metal fiber mesh or porous media, which are prone to dust accumulation and blockage during long-term operation, affecting mixing uniformity and combustion stability

3. Risk of backfire: The combustion speed of fully premixed gas mixture is relatively fast, and backfire may occur when the airflow speed is lower than the flame propagation speed

The engineering solutions for traditional fully premixed boilers in the above three aspects are often not comprehensive enough, leading to problems such as efficiency degradation, emission fluctuations, and frequent maintenance in actual operation.


3.2 Flat and spacious burner technology

Free Energy has independently developed a flat and spacious burner to address the pain points of traditional fully premixed burners, fundamentally solving the problems of dust accumulation, blockage, and frequent maintenance.

3.2.1 Structural Design

The flat and spacious burner adopts a flat plate structure design, with a flat combustion surface instead of traditional cylindrical or curved surfaces. Its core technical features include:

·Spacious airflow channel: The gas air mixture airflow channel inside the burner adopts a spacious design, with a cross-sectional area larger than traditional metal fiber mesh burners, and dust particles cannot accumulate in the channel

·Flat combustion surface: The flat combustion surface ensures uniform flame distribution, consistent heat flux density, and prevents local overheating

·Surface combustion method: The mixed gas undergoes flameless catalytic combustion on the outer surface of the burner, with invisible flames and high radiation heat transfer efficiency


3.2.2 Maintenance free feature

The core engineering value of the flat and spacious burner lies in "maintenance free":

maintenance project

Traditional metal fiber mesh burner

Flat and spacious burner

air filter

Must be configured and regularly replaced with filter cartridges

No configuration required

Burner cleaning

Clean once every 3-6 months

No need to clean

Dust accumulation treatment

When dust accumulation is severe, the machine needs to be dismantled and cleaned

No dust accumulation, no need for treatment

Burner replacement

After carbon deposition and burning, it needs to be replaced

Design lifespan synchronized with the host

Annual maintenance cost

2000-5000 yuan/year

Approaching zero

Traditional fully premixed boilers must be equipped with an air filtration system and regularly replace the filter element, otherwise the metal fiber mesh of the burner will cause uneven mixing, combustion deterioration, and NOx exceeding the standard due to dust accumulation. The flat and spacious burner fundamentally eliminates the problem of dust accumulation through a spacious channel design, without the need for an air filtration system, achieving long-term maintenance free operation.

3.2.3 Combustion performance

The flat and spacious burner, combined with the fully premixed combustion method, achieves the following combustion performance indicators:

·Uniform flame: The flat combustion surface ensures uniform flame distribution without localized high temperature zones

·Full combustion: 100% premixed and surface combustion, with a combustion efficiency close to 100%

·NOx<30mg/m ³: Low temperature flameless combustion+uniform temperature field, extremely low thermal NOx generation

·CO<100ppm: sufficient combustion, CO emissions far below the standard limit


Chapter 4: Intelligent Control System for Stepped Gas Proportional Valve

4.1 Technical bottlenecks of traditional fully premixed control

4.1.1 Passive regulation principle of Venturi

Traditional fully premixed boilers commonly use the Venturi tube principle to achieve gas air ratio matching: gas is not supplied through active valves, but is passively sucked in by the negative pressure generated at the throat of the Venturi tube during the operation of the variable frequency fan. The gas proportional valve can only be manually set to a fixed opening, and the fan speed forms a fixed linear relationship with the gas flow rate.

4.1.2 Three major drawbacks of passive regulation

Defect Type

mechanism

consequence

Security defects

The fan speed is a fixed ratio to the fixed gas valve. When environmental variables (altitude, fluctuation of gas calorific value, and changes in air temperature and humidity) change, the air-fuel ratio instantly becomes imbalanced

Easy to cause "bang bang" explosion or ignition failure, posing a safety hazard

Emission defects

Unable to adjust the air-fuel ratio in real time, the gas air ratio deviates from the optimal range when the load changes

NOx emissions are prone to exceeding standards and cannot meet strict environmental requirements

Efficiency deficiency

Fixed opening cannot adapt to different load conditions, excessive air at low loads increases exhaust heat loss

Partial load thermal efficiency significantly decreases, and the overall efficiency decreases throughout the year

4.1.3 Root cause of the problem

The root cause of the above problems lies in the traditional fully premixed system using open-loop control - the gas flow rate passively follows the wind turbine speed changes, without any feedback mechanism to correct the actual air-fuel ratio deviation. When the environmental conditions deviate from the design conditions, the system cannot adaptively adjust, resulting in a deterioration of combustion quality.

4.2 Self developed step-by-step gas proportional valve technology

4.2.1 Technical roadmap

Free Energy has introduced robot level stepper motor technology across borders, independently developed electric gas proportional valves, completely overturned the traditional passive regulation mode of Venturi, and achieved active and precise closed-loop control of air-fuel ratio.

4.2.2 System Architecture

The intelligent control system of stepper gas proportional valve consists of three core components:

┌─────────────┐     ┌──────────────────┐     ┌─────────────┐

│  变频风机    │←──→│  步进式燃气比例阀  │←──→│  氧传感器    │

│ (风量调节)   │    │  (燃气量调节)     │    │ (烟气含氧量  │

│             │    │                  │    │  实时反馈)   │

└─────────────┘     └──────────────────┘     └─────────────┘

      ↑                    ↑                       ↑

      └──────── 三者形成闭环联动控制系统 ────────┘

1. Variable frequency fan

Using a DC variable frequency fan, the speed is precisely adjusted according to the target heat load to control the supply of combustion air. The frequency conversion speed range covers 10% -100% load, with high adjustment accuracy and fast response speed.

Step by step gas proportional valve

Core innovative components. The gas valve is driven by a stepper motor, which has the following advantages:

· High precision positioning: The stepper motor can divide one rotation into hundreds to thousands of steps, and the valve opening adjustment accuracy can reach within 1%

· Drift free: The stepper motor adopts open-loop position control, which can accurately locate without position feedback and has no drift during long-term operation

·Quick response: millisecond level response speed, able to quickly adjust gas supply in case of sudden load changes

·High reliability: Robot grade stepper motors have a lifespan of tens of millions of actions, meeting industrial grade reliability requirements

3. Oxygen sensor

Installed in the smoke exhaust channel, it monitors the oxygen content in the smoke in real time. The oxygen content in flue gas is the most direct and accurate parameter reflecting the air-fuel ratio:

· When the excess air coefficient λ=1, the oxygen content in the flue gas is about 0% (theoretical complete combustion)

· When λ=1.15-1.25 (the optimal range for full pre mixing), the oxygen content in the flue gas is about 3-5%

· The oxygen sensor provides real-time feedback on the oxygen content of the flue gas to the controller, and the controller adjusts the opening of the step proportional valve accordingly

4.2.3 Dual axis linkage control logic

The system adopts a "dual axis linkage" control strategy:

4. Load command: The controller receives the target heat load command and calculates the required fan speed and gas valve opening

5. Synchronous regulation: The variable frequency fan and the stepper proportional valve act synchronously - the proportional valve opens synchronously when the fan accelerates, and closes synchronously when the fan decelerates

6. Oxygen sensing closed-loop correction: The oxygen sensor provides real-time feedback on the oxygen content of the flue gas, and the controller makes fine adjustments based on linkage to ensure that the air-fuel ratio is always locked in the optimal range

7. Millisecond level optimization: The system continuously and dynamically optimizes with millisecond level cycles, achieving adaptive compensation for environmental variables such as altitude changes, gas calorific value fluctuations, and air temperature and humidity changes

4.2.4 Control effect

Control Dimension

Traditional Venturi passive regulation

Active intelligent control of stepper proportional valve

Control method

Open loop (no feedback)

Closed loop (real-time feedback of oxygen sensing)

Air-fuel ratio accuracy

±10-15%

±1-2%

Environmental adaptation

Unable to adapt

Millisecond level dynamic compensation

Load regulation ratio

1:4-5

1:10

Explosive risk

High (when the air-fuel ratio is imbalanced)

Eliminate from the root

NOx stability

Large fluctuations, easily exceeding the standard when the load changes

Stable under all operating conditions<30mg/m ³

4.3 Intelligent Control System

The flat stacked fully premixed module furnace is equipped with a complete intelligent control system:

· 17 inch high-definition LCD touch screen: intuitive visualization of operating status, convenient parameter settings

· 485 serial port upper computer interconnection: supports integration of building automation systems to achieve centralized monitoring

· Remote control via mobile app: View operational status, adjust parameters, and receive alarms anytime, anywhere

· Multi terminal collaborative control: synchronization of local touch screen, computer upper computer, and mobile APP

· Intelligent adaptive load regulation: automatically adjust the number of module operations and the load rate of each module according to the actual heat load demand

· Fully automated operation: ignition, operation, and shutdown are fully automated, reducing the difficulty of on-site operation and maintenance management

Chapter 5 Modular System Architecture and Parallel Operation

5.1 Modular design concept

Traditional boilers usually adopt a single high-power design, which has the following problems:

· High investment threshold: It is necessary to invest in high-power equipment at once, with a large initial investment

· Redundant waste: Selecting based on peak load, running at low load most of the time, resulting in decreased efficiency

· Poor reliability: A single device failure can cause the entire system to shut down

· Difficulty in expansion: The increase in heat consumption requires the replacement of larger power equipment, and old equipment is scrapped

· Difficult to transport and install: high-power equipment has a large volume and weight, making it difficult to renovate and transport the computer room

The free energy flat square stacked fully premixed module furnace adopts a modular parallel architecture, which divides the system into multiple standardized independent modules to fundamentally solve the above problems.

5.2 Core Features of Modular Architecture

5.2.1 Independent modules

Each module is a complete independent heating unit, including:

· Flat stacked heat exchanger

· Flat and spacious burner

· Stepped gas proportional valve control system

· variable frequency fan

· Independent gas pipeline, waterway, and circuit interfaces

The parallel connection of gas pipelines, water pipelines, and circuits is achieved between modules through standardized quick connect interfaces.

5.2.2 Intelligent Scheduling

The control system automatically schedules the number of operating modules and the load rate of each module based on real-time heat load requirements

· Low load condition: Only start 1-2 modules and operate in the high-efficiency range

· Medium load condition: Start 2-4 modules and run each module at medium load

· High load condition: All modules are started and running at full load

· Load fluctuation: start and stop modules one by one to avoid frequent and significant adjustments and extend equipment life

Due to the single module adjustment ratio of 1:10 (10% -100% stepless adjustment), the overall adjustment ratio of the multi module combination system can reach over 1:80, covering a wide range of loads and maintaining efficient operation throughout the entire process.

5.2.3 Mutual backup

When multiple modules are running in parallel, each module serves as a hot backup for each other

· When any module needs maintenance or fails, other modules will automatically lift load compensation

· The system provides uninterrupted heating, completely solving the reliability problem of traditional single boiler "one failure and complete shutdown"

· Especially suitable for scenarios where heating interruption is not allowed, such as hospitals and hotels

5.2.4 Rotation operation

The intelligent control system automatically records the cumulative running time of each module and schedules the work sequence of each module in rotation according to the principle of "balanced wear and tear":

· Avoid premature wear caused by long-term high load operation of a single module

· The running time of each module tends to be balanced, and the overall system service life can be extended by 30-50%

· Similar to the principle of tire rotation in cars, balancing consumption and extending overall lifespan

5.2.5 On demand expansion

· At the initial stage of the project, the number of modules will be configured according to current requirements, and the initial investment will be precise

· In the future, when heat consumption increases, only modules need to be added without replacing the host

· No need to modify pipelines or expand the computer room

· The expansion cost is only the cost of adding new modules, with zero waste

5.3 Modular vs Traditional Single Unit Comparison

Comparison Dimension

Traditional single large boiler

Modular parallel system

Initial investment

A one-time large investment

On demand configuration, tiered investment

Load adaptability

Low load efficiency is poor

Efficient across the full load range

System regulation ratio

1:2-5

1:80+

Reliability

Once broken, stop completely

Mutual backup, without stopping the machine

Expansion method

Replace the whole machine

Add module

Maintenance impact

System wide shutdown

Single module shutdown, others running

Handling and installation

Difficulty (large equipment)

Convenient (standardized module)

service life

10-12 years

15 years+(rotation balanced wear and tear)

Chapter 6 Product Series and Technical Parameters

6.1 Flat stacked fully premixed low nitrogen condensing modular water heater

6.1.1 Core Performance Indicators

Performance Parameters

indicator value

Rated thermal efficiency

≥107%

flue gas temperature

≤45°C

NOx emissions

<30mg/m³

CO emissions

<100ppm

Rated pressure

1.0Mpa

water volume

<30L(Non pressure vessel)

Maximum hot water temperature

80°C

Applicable Water Pressure

0.05-0.7Mpa

Gas type

natural gas(1800-2800Pa)

Rated Voltage

220V

6.1.2 Single module technology selection table

project

unit

ZYRSDL-Q99

ZYRSDL-Q150

ZYRSDL-Q180

Module Configuration

—

Module 1

Module 1

Module 1

rated heat load

KW

99

150

180

Gas consumption (natural gas)

m³/h

≈10

≈15

≈18

Water production rate (temperature rise of 25 ° C)

L/h

3500

5250

6125

Heating area

㎡

600-1200

1200-1800

1500-2500

power consumption

KW/h

0.2

0.3

0.3

Machine appearance

mm

778×428×1126

778×428×1126

778×428×1126

Gross weight of the machine

kg

60

80

80

smoke vent

mm

φ100

φ100

φ100

Hot water outlet

—

DN25external thread

DN25external thread

DN25external thread

Gas inlet

—

DN25external thread

DN25external thread

DN25external thread

water inlet

—

DN25external thread

DN25external thread

DN25external thread

6.1.3 多模块组合技术选型表

project

unit

ZYRSDL-Q200

ZYRSDL-Q360

ZYRSDL-Q450

RGRSDL-Q720

ZYRSDL-Q1080

ZYRSDL-Q1440

Module Configuration

—

2 modules

2 modules

3 modules

4 modules

6 modules

8 modules

rated heat load

KW

200

360

450

720

1080

1440

Air consumption

m³/h

≈20

≈36

≈45

≈72

≈108

≈144

Water production rate (temperature rise of 25 ° C)

L/h

6805

12250

15750

24500

36750

49000

Heating area

㎡

2000-3500

3500-4500

4000-6000

6000-9500

10000-15000

13000-20000

power consumption

KW/h

0.5

0.5

0.7

1

1.5

2

Machine appearance

mm

728×808×1392

728×808×1392

1000×808×1392

1248×808×1392

1770×808×1392

1248×1748×1392

Gross weight of the machine

kg

130

130

400

500

700

1000

smoke vent

mm

φ150

φ150

φ250

φ250

φ250

φ300

Hot water outlet

—

DN50flange

DN50flange

DN50flange

DN65flange

DN80flange

DN100flange

Gas inlet

—

DN50flange

DN50flange

DN50flange

DN50flange

DN65flange

DN80flange

water inlet

—

DN50flange

DN50flange

DN50flange

DN65flange

DN80flange

DN100flange

6.2 Flat stacked fully premixed low nitrogen condensing modular steam generator

6.2.1 Core Performance Indicators

Performance Parameters

indicator value

thermal efficiency

≈107%

Maximum steam temperature

200°C

Maximum work pressure

1.0Mpa

NOx emissions

<30mg/m³

Gas consumption per ton of natural gas

<75m³

exhaust gas temperature

<45°C(PVC pipe smoke exhaust)

Furnace water volume

24.28L/Module(<30L,Non special equipment)

Heat exchange area (250L model)

36.55㎡

6.2.2 Technical parameter table

project

unit

ZYZQDL-250L

ZYZQDL-1000L

Module Configuration

—

Module 1

Module 4

rated heat load

KW

180

720

rated heat load

Wan Daka

15.5

60

rated evaporation capacity

L

250

1000

Furnace water volume

L

24.28

24.28×4

Instrument power

KW

1.5

1.5×4

Natural gas consumption

m³/h

≈18

≈75

Liquefied gas consumption

Kg/h

≈13

≈52

Gas pressure (natural gas)

Pa

2000-2500

2000-2500

Gas pressure (liquefied gas)

Pa

2800-4000

2800-4000

Rated Voltage

V

220

220

Gas inlet

—

DN25

DN40

water inlet

—

DN25

DN40

Steam outlet

—

DN25

DN40

smoke vent

mm

φ100

φ300

total machine weight

kg

330

1320

operating weight

kg

360

1380

Overall dimensions

mm

1050×600×1530

1800×1300×1800

6.2.3 Core advantages of steam generator

The flat stacked fully premixed modular steam generator has the following core advantages compared to traditional steam boilers:

1. Exemption from inspection and certification

The water volume of the furnace body is only 24.28L/module, far below the limit of 30L for special equipment. It does not belong to special equipment and does not require a registration certificate, annual inspection, or a certified boiler worker.

2. Efficient and energy-saving

The heat exchange area is 36.55 square meters (250L evaporation capacity), and the effective heat exchange area is increased by 300% compared to steam equipment such as boilers of the same power and through flow boilers. The gas consumption per ton of steam is less than 75m ³, and the thermal efficiency is about 107%.

3. Low temperature smoke exhaust

When the steam temperature is 200 ° C and the exhaust gas temperature is below 45 ° C, PVC pipes can be used for smoke exhaust, significantly reducing the cost of smoke exhaust engineering.

4. Flexible modules

A single module has an evaporation capacity of 180KW/250L, and up to 4 modules can be connected in parallel with an evaporation capacity of 720KW/1000L (approximately one ton of steam). Flexible investment can be configured as needed.

Chapter 7 Horizontal Comparative Analysis of Four Mainstream Boiler Structures

7.1 Comparing Dimensions and Objects

To objectively evaluate the technical positioning of the flat stacked fully premixed module furnace, four mainstream boiler structures on the market were selected for horizontal comparison:

· Free energy flat square stacking module furnace (316L flat square tube three-dimensional stacking)

· Traditional fire tube boiler (circular fire tube arrangement)

· Silicon cast aluminum boiler (integrated cast aluminum chamber)

· Fin module furnace (round tube with external fins)

7.2 Four dimensional comparative analysis

7.2.1 Core Structure Design

Boiler type

structural characteristics

advantage

Disadvantage

Flat stacked module furnace

316L flat square tube three-dimensional stacking, integrated molding

Minimize volume and maximize heat transfer area

The manufacturing process is complex and requires high precision brazing

Traditional fire tube boiler

Sparse arrangement of circular fire pipes

Simple structure and low manufacturing cost

Low space utilization and natural limitations in heat transfer

Silicon cast aluminum boiler

Integrated cast aluminum cavity

Good casting integrity and high thermal conductivity

Fixed flow channel, unable to stack, limited density

Fin module furnace

Round tube with external fins

Fins increase heat transfer area

Relying on external expansion and taking away heat through refrigerant flow rate

7.2.2 Volume and Space Occupation

Boiler type

Same power volume

Computer room requirements

Adaptability for renovation

Flat stacked module furnace

Minimum (Traditional 1/3-1/5)

Regular space is sufficient

Perfectly adapted to the renovation of old computer rooms

Traditional fire tube boiler

maximum

The height and load-bearing requirements are extremely high

Difficulty in renovation, often requiring the construction of new computer rooms

Silicon cast aluminum boiler

larger

The body is thick and heavy, and the parallel connection of multiple machines takes up a huge amount of space

Requires a large installation space

Fin module furnace

moderately large

A large amount of ventilation space needs to be reserved

The land occupation is relatively large, and the renovation is limited

7.2.3 Energy Efficiency and Compliance

Boiler type

thermal efficiency

NOx emissions

Pressure vessel qualification

Annual inspection requirements

Flat stacked module furnace

≥107%

<30mg/m³

Not required (<30L)

Exemption from annual inspection

Traditional fire tube boiler

90-92%

80-150mg/m³

Pressure bearing funds require special equipment

Mandatory annual inspection

Silicon cast aluminum boiler

95-100%

30-50mg/m³

Only supports normal pressure operation

No need for normal pressure version, pressure version requires annual inspection

Fin module furnace

95-100%

40-60mg/m³

The pressure bearing capacity of condensing pipe fittings is limited

Depending on the specific model

7.2.4 Material and Maintenance Life

Boiler type

Heat exchanger material

Corrosion resistance

Maintenance Requirements

design life

Flat stacked module furnace

316L stainless steel

Excellent (acid+alkali+high temperature resistance)

Maintenance free (ample burner without dust accumulation)

15 years+

Traditional fire tube boiler

Carbon steel

Poor (easily corroded by condensed water)

Frequent professional maintenance, severe carbon buildup

8-10 years

Silicon cast aluminum boiler

cast aluminum

Poor (not resistant to acid water, prone to leakage)

After leakage, it cannot be repaired and can only be replaced as a whole machine

8-12 years

Fin module furnace

Stainless steel+fins

Generally (fins are prone to carbon deposition, burning, and deformation)

Regularly cleaning the fins incurs high maintenance costs

10-12 years

7.3 Comprehensive evaluation

evaluation dimension

Flat stacked module furnace

Traditional fire tube boiler

Silicon cast aluminum boiler

Fin module furnace

Structural efficiency

★★★★★

★★

★★★

★★★

Volume advantage

★★★★★

★

★★

★★

energy efficiency level

★★★★★

★★

★★★★

★★★★

Emission level

★★★★★

★

★★★★

★★★

Compliance and convenience

★★★★★

★★

★★★

★★★

Material lifespan

★★★★★

★★

★★

★★★

maintenance cost

★★★★★

★★

★★

★★

Overall Rating

★★★★★

★★

★★★

★★★

The flat stacked fully premixed modular furnace achieved the highest scores in all seven evaluation dimensions, demonstrating its systematic and comprehensive technological advantages. It is not a single dimensional improvement, but rather an intergenerational leap achieved from five levels: structure, combustion, control, materials, and compliance.

Chapter 8 Application Scenarios and Selection Guidelines

8.1 Application scenarios of water heaters

The flat stacked fully premixed modular water heater is suitable for the following commercial and industrial hot water/heating scenarios:

Scene Type

Typical User

Thermal characteristics

Recommended Configuration

Recommended Model

Hotel hot water

Business hotels, vacation hotels, chain hotels

Concentrated peak water usage (morning and evening), with significant load fluctuations

2-4 modules in parallel

ZYRSDL-Q360~Q720

Hospital heating

Comprehensive hospitals, specialized hospitals, rehabilitation centers

24-hour uninterrupted, with extremely high reliability requirements

Parallel connection of 3-6 modules (as backup for each other)

ZYRSDL-Q450~Q1080

school dormitory

Universities, middle schools, and training bases

High water consumption during peak hours in the morning and evening, and low valley during the day

2-4 modules in parallel

ZYRSDL-Q360~Q720

Factory process hot water

Food processing, textile printing and dyeing, chemical industry

Process constant temperature requirement, continuous heating

4-8 modules in parallel

ZYRSDL-Q720~Q1440

commercial complex

Shopping centers, office buildings, apartments

Balancing heating and domestic hot water

Parallel connection of 3-6 modules

ZYRSDL-Q450~Q1080

Regional heating

Residential communities and industrial parks

Central heating, load varies with temperature

6-8 modules in parallel

ZYRSDL-Q1080~Q1440

Bath hot water project

Hot springs, bathhouses, swimming pools

Large water volume, constant temperature supply

4-8 modules in parallel

ZYRSDL-Q720~Q1440

8.2 Application scenarios of steam generator

The flat stacked fully premixed modular steam generator is suitable for the following industrial steam scenarios:

Scene Type

Typical User

Characteristics of using steam

Recommended Configuration

food processing

Steaming, sterilization, drying

Intermittent use of steam, high hygiene requirements

ZYZQDL-250L~1000L

Brewing and Distillation

Baijiu, beer, alcohol

Continuous use of steam with high quality requirements

ZYZQDL-1000L

textile printing and dyeing

Forming, steaming, and washing with water

Continuous use of steam, stable load

ZYZQDL-1000L

Washing and ironing

Large laundry and clothing factories

Intermittent use of steam, large load fluctuations

ZYZQDL-250L~1000L

biopharmaceutical

Sterilization, extraction, and drying

High steam quality and reliability requirements

ZYZQDL-250L~1000L

Paper packaging

Drying and shaping

Continuous use of steam

ZYZQDL-1000L

Breeding and slaughtering

Slaughtering, scalding, and disinfection

Intermittent use of steam

ZYZQDL-250L

Industrial and Chemical Industry

Reaction heating, distillation

Continuous use of steam with strict parameter requirements

ZYZQDL-1000L

8.3 Selection Calculation Method

8.3.1 Selection of Water Heater

Step 1: Calculate the heat load

· Heating heat load: Q ₁=heating area x unit area heat load (W/㎡)

-Residential: 50-80 W/㎡

-Office: 60-100 W/㎡

-Factory building: 100-150 W/㎡


· Domestic hot water heat load: Q ₂=water consumption x temperature rise x specific heat capacity/heating time

Step 2: Select the number of modules

Number of modules N=Total heat load/Single module heat load (rounded up)

Step 3: Verify the load adjustment ratio

Ensure that the minimum load is greater than the minimum load of a single module (10% of rated power), and avoid frequent starting and stopping.

8.3.2 Selection of Steam Generator

· Calculate the maximum steam demand (L/h)

· Choose single module (250L) or multiple modules (up to 4 modules/1000L)

· Converted based on 720KW=approximately one steam ton

8.4 Installation Convenience

The installation of flat stacked fully premixed module furnaces has significant advantages:

· Small size: The single module has a shape of only 778 × 428 × 1126mm, with a gross weight of 60-80kg, and can be transported by ordinary elevators

· General equipment: Non special equipment, no special installation qualification required

· Easy installation: standardized quick connect interface, quick connection of water, electricity and gas pipelines

· Can be expanded at any time: reserve module positions, future module additions do not require modification

· Easy smoke exhaust: The exhaust temperature is less than 45 ° C, and PVC pipes can be used for smoke exhaust without the need for stainless steel chimneys

Conclusion

The free energy flat square stacked fully premixed module furnace has achieved intergenerational technological breakthroughs in commercial and industrial heating fields with three self-developed core technologies - flat square tube precision stacked heat exchanger, flat plate wide width burner, and intelligent control system of step gas proportional valve.

The technical value of this product is reflected in five aspects:

8. At the structural level, precision stacking of flat square tubes achieves a face to face ratio of 1.6-1.8, with a volume of only one-third to one-fifth of traditional power, and a heat transfer area 3-4 times larger

9. Combustion layer: fully premixed surface combustion+flat plate ample burner, thermal efficiency ≥ 107%, NOx<30mg/m³, Maintenance free operation

10. Control level: stepper motor dual axis linkage+oxygen sensing closed-loop, adjustment ratio 1:10, precise locking of air-fuel ratio under all operating conditions

11. Compliance level: Non pressure vessels with a water volume of less than 30L are exempt from inspection, certification, annual inspection, and boiler operation

12. System level: Modular parallel connection, mutual backup without shutdown, on-demand expansion with zero waste, rotating operation to extend lifespan

Free Energy will continue to uphold the principle of "making heating simpler, safer, energy-saving, intelligent, and durable", adhere to the independent research and development technology route, drive product upgrades with technological innovation, provide users with more efficient, environmentally friendly, and reliable thermal solutions, and strive to become a practitioner of Chinese style thermal freedom.

Foshan Free Energy Electrical Appliance Co., Ltd

Heshan Free Energy Electrical Appliance Factory

Contact phone number: 18038757576

Official website: hszyn.com

*The copyright of this white paper belongs to Foshan Free Energy Electrical Appliance Co., Ltd. Without permission, it is not allowed to copy, excerpt or use for commercial purposes. If there are any updates to the technical parameters, the latest product manual shall prevail*

Name:
Message:
Verification code:
Submit
Comment
contact us
电话 18038757576
QQ 453457997
微信
扫码咨询