The most commonly used independent heating system for households is a gas wall mounted boiler, which heats water through the boiler and pressurizes the water pump to form a hot water circulation for heating. There are three main types of gas boilers commonly used in the market: sleeve type gas boilers, plate exchange type gas boilers, and condensing type gas boilers. Although gas boilers still have exhaust emissions, they are still a common heating method for some low-income households.
Plate exchange boiler
The difference from sleeve boilers is that when using domestic water, the boiler is specially equipped with a heat exchange plate. The heating water circuit is cut off by switching the electronic three-way valve inside the boiler, allowing the heated hot water to form a small circulation inside the boiler and exchange heat with the domestic water through the plate. So, in terms of constant water temperature, plate exchange boilers have certain advantages and a longer service life than casing boilers.
Casing boiler
The combustion fire is directed upwards, which is consistent with plate exchange boilers. Why is it called a sleeve? It is because the heating carrier is the sleeve method. Whether it is for underfloor heating or domestic water use, the heating part is located at the top of the furnace, and continuous heating of the sleeve will have a certain impact on its service life. So, among the three types of boilers, the quality of the casing boiler is the lowest end product.
condensing boiler
The flame of a condensing boiler burns downwards, and its characteristic is to reuse the combustion exhaust gas. After the combustion of natural gas, the temperature of the exhaust gas is very high. If it is directly discharged from the flue, a large amount of heat is lost in the atmosphere, which not only harms the atmosphere but also wastes energy. Therefore, its characteristic lies in the recovery of heat from the flue gas, reducing direct energy loss.
current situation
Traditional heating in China often uses two types of boilers: sleeve and plate replacement, while the European market is mainly dominated by condensing furnaces. Regardless of the type of gas boiler, there is no way to solve the problem of emitting pollutants. This conflicts to varying degrees with the low-carbon emission reduction advocated by the country, but from the situation, it is not realistic to achieve this change in a short period of time. The two main boiler factories in China, Wanhe Boiler and Xiaosquirrel Boiler, still mainly produce gas plate replacement boilers. Some other boiler manufacturers have not exceeded the production scale and technological research and development capabilities of these two companies. Foreign boiler manufacturers mainly import boilers from Germany and Italy.
Introduction to plumbing system
The household gas boiler type water heating system is abbreviated as a sub unit water heating system or water heating system. It mainly consists of the following components:
(1) Heat source part - household gas small boiler
(2) Control section - water separator, solenoid valve, and temperature controller
(3) Heat dissipation part - water coil or radiator. Its working principle is to assemble the above components into a closed circulation system, and use a "household gas small boiler" to continuously heat up the cold water that flows back through the "water coil or radiator" before entering the system circulation. The function of the "water divider and solenoid valve" is to use the means of cutting off or connecting hot water to achieve the purpose of controlling each independent heating area separately.
From this, it can be seen that the water heating system utilizes "water" as a heat source carrier, and achieves the heating requirements of each area by controlling the flow of "water flow" in each heating area.
Why is this seemingly perfect system so popular in practical use?
The Secret of Gas Boiler
The gas boiler is the core heat source of the entire water heating system. Its working principle is similar to the common "home gas water heater", but with a higher power. Generally ranging from 20kw to 36kw. The power of a "home gas water heater" is around 16kw (the power of a "home gas stove" is around 4kw). Regardless of the type of boiler, it is best to use natural gas as the gas source, as the calorific value of natural gas is 8500 kcal, much higher than the calorific value of artificial gas, which is 3500 kcal.
Since the "gas boiler" is the core of the entire water heating system, it has to bear the main responsibility for the high energy consumption problem of water heating. Let's take a look at the secret hidden behind the 'boiler'?
boiler thermal efficiency
All manufacturers of "gas boilers" claim that their "boiler thermal efficiency reaches over 90%". So, should we assume that at least 90% of the natural gas burned in the boiler is absorbed by water? wrong! Boiler thermal efficiency "refers to the ability of a boiler to convert coal gas, natural gas, and other gases into thermal energy. That is, the ability of the boiler itself to burn fully. As for how much heat energy is absorbed by the boiler combustion when water is heated in the boiler, it is not completely related to the "boiler thermal efficiency".
chimney
As is well known, where there is a stove, there must be a chimney. The higher the chimney, the more fully the furnace burns. However, all chimneys of "gas boilers" are only designed with a length of 1 meter for ease of installation and aesthetic appearance. This creates a contradiction: if the chimney is short, the boiler cannot burn fully. A large amount of heat energy is discharged into the outdoor air through the chimney in vain. After on-site testing, the temperature at the chimney outlet of a famous German brand is 120 ℃. The air outlet temperature of the vast majority of "household gas boilers" is above 160 ℃, and some even reach 200 ℃.
Minimum output power
All "technical parameter" tables of "household gas boilers" clearly indicate the values of "maximum output power" and "minimum output power" of the heating system. So, what is' minimum output power '? Why is there a 'minimum output power'? How small is the minimum output power?
The 'minimum output power' refers to the minimum amount of combustion that must be achieved when the boiler is operating during combustion. That is to say, when the boiler output power required for heating area is less than the "minimum output power", the boiler still burns at the "minimum output power". Of course, the excess heat is discharged into the air through the chimney. In short, if only 10 square meters are used for heating in a 100 square meter room, the boiler will still operate at the combustion rate of 50 square meters for heating.
The design of "minimum output power" for gas boilers is based on considerations of boiler safety. Because once the chimney leading to the outside encounters strong outdoor airflow and backflow, it is easy to extinguish the fire and cause large-scale gas leakage accidents. The design of the gas boiler ensures that the boiler can still operate normally and safely in various harsh environments.
The 'minimum output power' is generally half of the 'maximum output power'. After the above analysis, we understand a truth. The energy of boiler combustion=the energy of heating hot water+the energy discharged from the chimney.
cooling system
There are two types of cooling systems for gas boiler water heating systems. One is the underground water coil, and the other is the wall mounted radiator. Both of these heat dissipation methods utilize hot water (65 ℃) flowing through the pipe to exchange heat with the outside through the pipe wall. In order to increase the heat dissipation area of this heat dissipation method, the underground water pipes and wall radiators are designed with multiple S-shaped spiral structures. In terms of heating effect, the heat dissipation method of underground water coils is much better than that of radiators.
We know that the optimal underfloor heating mode is when the ground temperature in contact with the human body (40 ℃) is slightly higher than body temperature, and the overall ambient temperature is comfortable but not too hot (18 ℃ -20 ℃). Because plumbing pipes are standard linear high-temperature heating elements, in order to meet the heating requirements of the entire floor. Water heating pipes have to bend back and forth on the ground to increase their heat dissipation area. The purpose is to transform linear high temperatures into planar low temperatures. The change in this heat dissipation mechanism comes at the cost of sacrificing thermal efficiency.
control system
The control system of the plumbing system consists of a water separator, solenoid valve, and temperature controller. The water separator and solenoid valve are designed for users to independently control certain heating areas. Taking a 100 ㎡ unit as an example, theoretically, its heating only needs to connect a water outlet pipe from the boiler, complete the coil indoors, and then return to the boiler. However, in practice, due to the limitations of water pipe length, water pressure strength (the longer the water pipe and the more bends there are, the greater the water pressure required), and user habits, several coils are often required to coexist. The purpose of a water separator is to introduce the hot water from the boiler into each coil system separately. For example, one way to the living room, one way to the bedroom, one way to the bathroom, etc. The purpose of solenoid valves is to receive user instructions on the temperature controllers in each room, and to automatically cut off or turn on the hot water introduced into each coil system. The control system for plumbing has been tested in practice and found to have many safety hazards.
(1) The use of water dividers increases the probability of system leakage. Because the number of water pipe joints has increased by 5-6 times.
(2) The system's dependence on the reliability of external components has increased. Any malfunction of any component in the solenoid valve or temperature controller can lead to misoperation of the entire plumbing system. And the solenoid valve and thermostat are precisely the components that are most prone to malfunction.
Installation method
The installation of plumbing systems is quite time-consuming and labor-intensive. After laying the water coils and control lines, the plumbing company will notify the water distributor factory and boiler factory to install the water distributor and boiler on-site. Finally, install the temperature controller and debug the system. The generally allocated installation hours are: 2 days for pipelines, 2 days for boilers, and 1 day for commissioning (taking a 100 ㎡ unit as an example). This does not include the additional installation time required due to the coordination between the previous and subsequent processes.
System security
The safety of the water heating system is actually the safety of the entire heating water system. When it comes to "security", people can't help but think of what kind of situation will arise when "unsafe" situations occur after the "security" of the system disappears? Is this situation within a foreseeable and controllable range?
Anyone would guess that the only 'unsafe' consequence of a plumbing system is water leakage! And it is precisely this' only 'consequence that creates an inherent and insurmountable flaw in the plumbing system. Water has the characteristic of bursting whenever there is space and taking advantage of every opportunity. Based on the current level of technology, the method for people to detect water leakage is to wait for it to leak and wait for it to leak! When a person's naked eye detects a leak, it is often already "overflowing with water". The losses it has caused are almost irreparable. Since no water leakage can be foreseen, it is even more impossible to talk about "controlling water leakage".
service life
The service life of a plumbing system is composed of the service life of its constituent components.
(1) Gas boiler: The overall lifespan is 10-15 years, and its core combustion components are replaced within 3-5 years (at one's own expense).
(2) Water divider: usually 8 years, there is system leakage maintenance.
(3) Underground coil: 50 years.
(4) Heat sink: 15 years.
(5) Thermostat: 3-8 years (domestic, imported).
maintenance cost
The maintenance cost of the plumbing system is quite high. Firstly, before the arrival of winter each year, it is necessary to check whether the entire system can be turned on normally. Whether the main components are rusted or scaled. Secondly, due to the presence of a large number of microorganisms in water, under suitable conditions, a large amount of biofouling will be produced. The biofouling will cover the inside of the pipe wall, causing the pipeline to turn green and black. According to relevant data statistics, in geothermal heating systems, an average of 1mm of scale will form per pipe, and this 1mm thick scale can cause the water temperature to drop by 6 ℃. This not only affects the normal operating temperature, but also causes energy waste. If not effectively cleaned for a long time, the geothermal heating system will malfunction, causing blockages inside the pipe that cannot be used, and even causing damage to the ground, dismantling or replacing the geothermal pipeline system, causing property losses and inconvenience to geothermal heating users. Geothermal heating systems mainly use specially designed pipelines. Loop structure, currently mostly PP-R and PEX As a geothermal pipeline laid on the ground, the shape of the geothermal coil is complex and the pipeline is long. Due to changes in water supply temperature, calcium and magnesium ion scale will adhere to the inner wall of the pipeline for a long time. If not treated regularly, it will also cause a temperature drop, directly affecting the heat dissipation effect. The blockage of geothermal coils has become a prominent problem restricting the development of the underfloor heating market. (Taken from the public information of a well-known water pipe cleaning company). Therefore, underground water pipes need to be cleaned at least once every two years. Again, the combustion furnace plate of the boiler needs to be replaced every 3 to 5 years. Finally, always pay attention to the leakage of the water separator. Do 'replace any leaks'!
Usage cost
The high cost of using gas-fired water heating boilers has become an open secret in the industry. According to the survey, the monthly gas cost for a 100 square meter unit in winter is over 1800 yuan. The winter heating cost for a villa of over 200 square meters can reach over 4000 yuan per month. With the adjustment of national energy policies and the significant increase in coal, gas, and oil prices, the use of gas powered water heating systems will inevitably be impacted. The annual increase in usage costs is an irreversible trend.
Maintenance Method
1、 Before use, it is necessary to check whether the coaxial flue is blocked;
2、 When not using the boiler in winter, it is necessary to set the boiler in an antifreeze state to prevent freezing and cracking;
3、 Prevent gas leakage. During use, conduct a user self inspection every two months and replace the gas hose every two years;
4、 The boiler water supply temperature has a wide range of settings. Do not turn off the machine when not in use during the day, set it to the lowest temperature;
5、 Do not set the room temperature too high, generally 18 ℃ to 20 ℃ is appropriate.
6、 Under no circumstances shall users disassemble, repair, or change the purpose of the boiler.
7、 It is strictly prohibited to dismantle or modify natural gas pipelines and facilities.
8、 In winter, the frequency of opening windows for ventilation should be reduced.
Environmental impact
During combustion, gas-fired water heating boilers emit a large amount of unburned carbon monoxide, sulfur dioxide, and carbon dioxide gas from the chimney. According to tests, the equivalent amount of harmful gases emitted from a gas boiler chimney is equivalent to the exhaust emissions of a motorcycle. The pollution to the environment is extremely serious. In addition, nowadays, the vast majority of gas boilers use natural gas as their main gas source. Who knows, natural gas itself is rich in more than 1800 chemical raw materials and is an important strategic substance. Using it for heating itself is a huge waste of resources.
The advantages of automatic regulation of household gas boilers are becoming more and more popular among users. How to make home heating more cost-effective? Parez Boiler teaches you several life tips.
Users who have newly opened the heating system can first turn on the valve for heating, set the temperature to the highest, and after the indoor temperature of the radiator remains constant, adjust the valve to the appropriate temperature. At the same time, the energy consumption is also the highest during this period, and the heat energy consumption will gradually decrease after normal use.
When resting at night, the room temperature should not be too high. It is generally recommended to be between 16 ℃ and 18 ℃, as this makes people feel more comfortable. For rooms, kitchens, bathrooms, and other areas that are not occupied for a long time, the temperature should be set to around 8 ℃, and the heating system and plumbing system of the room should be protected against freezing. The commonly used materials for the cooling fins of household gas boilers nowadays are copper and aluminum alloy, each with its own advantages and disadvantages. Copper has good thermal conductivity, but it is expensive, difficult to process, heavy (many pure copper heat sinks exceed the weight limit of CPUs), has a small heat capacity, and is prone to oxidation. However, pure aluminum is too soft to be used directly. Only aluminum alloy can provide sufficient hardness. The advantages of aluminum alloy are low price and light weight, but its thermal conductivity is much worse than copper. Some radiators take advantage of each other and embed a copper plate on the aluminum alloy radiator base.
For office workers, it is not recommended to close all radiator valves of household gas boilers after work. Therefore, when there is no one around during the day, the room temperature is set to around 12 ℃. The specific setting depends on each person's feelings, and a certain room temperature is maintained to prevent the temperature from being too low and affecting comfort when entering the room at night. Because after being completely closed, the room temperature will drop significantly.
Just as frequent starting of a car consumes more fuel, opening the valve after work not only takes several hours for the room temperature to reach comfort, but also consumes more heat, which is not economical. Users who charge according to the heat meter have tricks when using temperature control valves.
Some tips for using household gas boilers: There are tips for using heating, and users can achieve energy-saving and efficient insulation effects through scientific adjustment. For users who charge by area, they should try to minimize frequent opening and closing of doors and windows or opening windows for ventilation during use, avoid hanging clothes or installing heating covers on household gas boiler radiators, and ensure normal heat dissipation of the radiators. Users can adjust the temperature control valve to a low temperature state when going out, which can effectively maintain indoor temperature and humidity, and more importantly, can greatly save energy consumption.