A boiler is a special equipment used for heating and industrial purposes. In terms of household heating, there are mainly two types: providing hot water and steam, such as household hot water and bathing water. Industry mainly provides steam to provide cooling, power and other services for other equipment, such as ships, locomotives, mines and other places. The working principle of boilers is relatively complex, mainly composed of fuel system, flue gas system, steam water system, etc.
The working principles of different types of boilers are also different. According to the size of the heating and service objects, it can be divided into the following three categories: household boilers mainly include electric boilers (electric hot water boilers), small gas boilers, wall mounted boilers, etc; The central heating boilers in residential areas, hospitals, companies, etc. mainly include gas boilers and steam boilers; Large heating units include coal-fired boilers, oil fired boilers, gas boilers, steam boilers, etc.
A boiler is a special equipment used for heating and industrial purposes. In terms of household heating, there are mainly two types: providing hot water and steam, such as household hot water and bathing water. Industry mainly provides steam to provide cooling, power and other services for other equipment, such as ships, locomotives, mines and other places. The working principle of boilers is relatively complex, mainly composed of fuel system, flue gas system, steam water system, etc.
The working principles of different types of boilers are also different. According to the size of the heating and service objects, it can be divided into the following three categories: household boilers mainly include electric boilers (electric hot water boilers), small gas boilers, wall mounted boilers, etc; The central heating boilers in residential areas, hospitals, companies, etc. mainly include gas boilers and steam boilers; Large heating units include coal-fired boilers, oil fired boilers, gas boilers, steam boilers, etc.
coal-fired boiler
Fuel and smoke air system
The main fuel used for boilers in our country is coal. Generally, large boilers and power plant boilers often burn coal powder, so there needs to be a pulverizing system that grinds raw coal into coal powder. As shown in the figure, the coal falling from the raw coal bin is fed into the coal mill for grinding by the coal feeder. During the coal grinding process, coal is dried simultaneously using hot air as the drying medium. Cold air is sent into the air preheater by the blower, where it absorbs the heat from the exhaust and becomes hot air. A portion of the hot air enters the coal mill after passing through the high-pressure head of the coal discharge machine. While heating and drying the coal, it carries the ground coal powder away from the coal mill. It can be seen that this part of the hot air not only serves as a drying medium, but also plays a role in transporting coal powder. This part of the hot air is usually called primary air. In the direct blowing system shown in the figure, the gas powder mixture is sent directly to the burner through the coal powder pipeline after coming out of the coal mill, and is sprayed into the furnace for combustion by the burner. It should be pointed out that in the intermediate storage type powder making system, the primary air carries coal powder into the coal powder separator, where the coal powder is separated from the airflow and stored in the coal powder bin. According to the load requirements, an appropriate amount of coal powder is supplied from the coal powder bin to the burner through the powder feeder. From the figure, it can also be seen that another part of the hot air coming out of the air preheater directly enters the furnace through the air distribution port of the burner to provide the air required for coal powder combustion. This part of the hot air is called secondary air.
The combustion of coal powder in the furnace releases a large amount of heat, and the temperature at the center of the flame is high. A water-cooled wall composed of metal pipes is laid on the inside of the furnace, and the heat released by combustion is mainly absorbed strongly by the heating surface of the water-cooled wall in the form of thermal radiation. However, due to the limitations of heat load and furnace volume, the flue gas temperature at the furnace outlet is generally still as high as around. In order to utilize this high-temperature flue gas, the flue is also equipped with heating surfaces such as superheaters (divided into several stages), reheaters, economizers, and air preheaters in sequence. High temperature flue gas sequentially flows through these heating surfaces and releases heat to them through convection, radiation, and other heat transfer methods. The exhaust temperature from the air preheater is generally around. At this point, the flue gas can no longer be reused and is sent to a dust collector for separation, removing the majority of the fly ash carried by the flue gas. It is then introduced into the chimney by a induced draft fan and finally discharged into the atmosphere.
Soda system
During the entire process of steam generation, the working fluid needs to go through three heating stages in the boiler. Firstly, the boiler feedwater is heated to saturated water, and then sequentially heated to saturated steam and superheated steam with a certain superheat temperature. These three processes are usually completed separately in the economizer, water-cooled wall, and superheater heating surface.
When the boiler is running, the feedwater is treated and deoxygenated, then pressurized by the feedwater pump and flows through the high-pressure heater before entering the inlet manifold of the economizer. Generally speaking, in the economizer, the feedwater is heated to saturated water. But in reality, the situation of different boilers also varies. For example, low-pressure small industrial boilers using cast iron economizers generally do not heat the feedwater to saturated water; For medium pressure boilers, it may be required that the working fluid at the outlet header of the economizer has a high saturation steam content; For boilers above subcritical pressure, it may be required that the working fluid at the outlet header of the economizer is unsaturated water with significant enthalpy deficiency. The working fluid flows from the outlet header of the economizer into the steam drum through a conduit, and during this process, the working fluid flows under the forced action of the feedwater pump. After entering the steam drum, the working fluid flows into the lower header of the water-cooled wall along the downcomer, and is distributed to each water-cooled wall tube (i.e. the riser) to enter the furnace for heating, forming a steam water mixture and returning to the steam drum. The flow in this section is maintained by the density difference between the steam water mixture in the downcomer and riser. After the steam water mixture returns to the steam drum, it is separated by the steam water separation device in the steam drum. The steam is concentrated in the steam space in the upper half of the steam drum, while the water enters the water space in the lower half of the steam drum and begins a new natural circulation flow. For high-pressure boilers, generally, some water evaporates into saturated steam every cycle.
After the saturated steam in the steam drum is separated, it is introduced into the superheater through a conduit for superheating. When the superheated steam is heated to the rated temperature, it is transported to the turbine for power generation. The boiler shown in the figure is equipped with a reheater in its convection flue. The steam coming out of the high-pressure cylinder of the steam turbine is led to the reheater for reheating. After reaching the required temperature, the reheated steam is reintroduced into the middle and low pressure cylinders of the steam turbine through the reheated steam outlet for expansion and work.
Gas fired hot water boiler
water system
Tap water enters from the cold water pipe, which is equipped with a cold water solenoid valve, one-way valve, gate valve, and bypass gate valve. The function of the cold water solenoid valve is to automatically control the intake of cold water. When the cold water solenoid valve is opened, the cold water enters the gas boiler through the pipeline; When the cold water solenoid valve is closed, the pipeline is cut off and the cold water stops flowing. The function of a one-way valve is to prevent hot water from flowing back and cold water from mixing. The bypass gate valve serves as a backup channel for temporary cold water intake when the cold water solenoid valve fails.
Gas channel system
The gas channel is equipped with pressure gauges, ball valves, filters, pressure reducing valves, flow meters, combustion engine valve groups, etc. Gas is used as the fuel for the combustion engine, and the fuel is burned in the furnace chamber of the gas boiler. The high-temperature flue gas flows backward along the furnace chamber and enters the first flue tube bundle through the combustion chamber. Then, it enters the second flue tube bundle through a 180 ° bend in the compression type front smoke box, and finally enters the tail flue after convective heat exchange. The flue gas is discharged into the atmosphere through the chimney. The atmospheric hot water boiler is equipped with an exhaust pipe connected to the atmosphere on its body, which does not bear any pressure. This is the biggest difference between it and high-pressure boilers. When the hot water reaches the set temperature, the cold water solenoid valve opens and uses the pressure of the cold water to push the hot water that has been heated in the boiler through the upper circulation pipe into the insulated water tank. At the same time as the hot water in the gas boiler flows to the insulated water tank, cold water is refilled from the cold water pipe. The insulated water tank is connected to a hot water pipeline to provide hot water. The pipeline is equipped with a hot water solenoid valve, which can provide users with selective hot water supply according to time. The bypass gate valve next to the solenoid valve can bypass the hot water solenoid valve and directly connect to the pipeline for long-term water supply. The insulated water tank is equipped with a liquid level probe, and when the water tank is filled, the boiler automatically stops boiling water. The water tank is equipped with a temperature probe. When the water temperature drops to the set temperature, hot water is pumped into the boiler through the circulating water pump of the lower circulation pipe for reheating.
electric control system
The gas boiler adopts an automatic control system, which is the control center of the entire gas hot water boiler system. Users adjust the operation of the hot water boiler system through the automatic control system.
electric boiler
When the electric boiler reaches the heat storage period, the water replenishment electric valve will be opened, and the heat storage water tank will begin to replenish water. When the water level reaches the predetermined high water level, the water replenishment electric valve can close on its own. When the temperature of the heat storage water tank reaches the preset temperature or the heat storage period ends, the electric boiler stops working. One minute later, the circulating pressure pump starts to stop running, and the circulating pressure pump runs at the set frequency. After 30 seconds, the electric boiler starts running and begins to store heat.
Open the water supply electric valve, close the thermal storage electric valve, start the circulating pressure pump to supply water in a variable frequency speed regulation constant pressure manner, and after about 30 seconds, start the electric boiler to supply water to the user in a direct supply manner. At the end of water supply, stop the circulating pressure pump first, and then stop the electric boiler after 60 seconds.
When the water supply period arrives, the electric valve for supplying water to the electric boiler is opened, the electric valve for storing heat is closed, the electric boiler does not work, and the circulating pressure pump is used for variable frequency speed regulation and constant pressure water supply. The electric valve for replenishing water during the water supply period of the electric boiler is always closed, and no replenishment operation is carried out to avoid supplying cold water to the user. If during the heat storage period and the temperature of the heat storage water tank is lower than the set temperature by 5 ℃, the circulating pressure pump will be put into operation again, and the electric boiler will start working after 30 seconds.